DIN Rail Time Relay Switch Digital LCD Programmable Timer

$29.99

Programmable timer for use in AC switching applications. Onboard battery maintains time and settings. DIN rail mountable.

Compare
SKU: YP15A Category: Tags: , ,

Description

Programmable timer for use in AC switching applications. Onboard battery maintains time and settings. DIN rail mountable.

Description:

*Digital Programmable Timer Switch,to-the minute setting accuracy and easy to use.

*DIN Rail Installation.

*Advanced pre-setting one week before.

*Digital electronics general purpose time switch daily and weekly programs.

*Repeat programs with 16 on/off setting.

*Built-in Lithium battery power reserve when electric supply cut off.

*LCD displays real time to Hour/Minute and ON/AUTO/OFF.

*This timer can be Used widely to control the Led lamp, Led strip, water heater, sprayer, bottler, preheater, agriculture facilities, broadcasting equipment, home appliance, etc.

Features:

*Item Condition:100% Brand New

*Material:ABS

*Color: White(As Pictures Show)

*Working voltage: DC12V /DC24V/AC110/AC220V(Optional)

*Dimensions:86*36*65mm/3.39’’x1.42’’x2.56’’(Approx.)

Specifications:

*Voltage limit: AC 180V-264V(50/60Hz)

*On/off operation: 8on & 8off

*Power:4.5VA (MAX)

*Bound:1 min ~168 hours

*Battery backup: >=15days

*Display: LCD

*Minimum interval: 1 minute

*Count down: 1 sec~99 min 56 sec

*Pulse: 1 sec~59 min 59 sec

*Load capacity: resistive load: 16A/250V AC

*Lagging load: 10A/250V AC

*Lamp Load: 2000W

*Switching Contact: 1 changeover switch

*Operating termperature: -10 ~ +55 Centigrade

*Ambient humidity : 35-85%RH

 Package Contents

1* Digital Programmable Timer


Operating instructions:
               1.Connect to the rated power supply and press “reset” when starting use.
               2.The default setting of timer is 24 hour mode,if want to switch to 12 hours mode,please press “111 1 - DIN Rail Time Relay Switch Digital LCD Programmable Timer -Programmable timer for use in AC switching applications. Onboard battery maintains time and settings. DIN rail mountable. - timers-and-controls - 111 1” for 5 seconds,LCD                     display”AM”,if want to switch back to 24 hour mode,please press “111 1 - DIN Rail Time Relay Switch Digital LCD Programmable Timer -Programmable timer for use in AC switching applications. Onboard battery maintains time and settings. DIN rail mountable. - timers-and-controls - 111 1” for 5 seconds.
               3.Programmable setting:
               Process                                   Key-press                                            Setting
               A                                              press”P”                                             Display “on” and “1” setting the first group ON time
               B                                              press”D+”                                           Setting the ON time one day or several days of a week
               C                                              press”H+/M+”                                     Setting the hour and min of ON time
               D                                              press”P”                                             Display “off” and “1” setting the first group OFF time
               E                                              press”P”                                             Setting the OFF time one day or several days of a week
               F                                              press”H+/M+”                                      Setting the hour and min of OFF time
               G                                             repeat the process of “A” to “F”              Setting the second to eighth group ON and OFF time
               4.Full time clock setting
               (1)press the “111 1 - DIN Rail Time Relay Switch Digital LCD Programmable Timer -Programmable timer for use in AC switching applications. Onboard battery maintains time and settings. DIN rail mountable. - timers-and-controls - 111 1” and “D+” at same time to set the week.
               (2)press the “111 1 - DIN Rail Time Relay Switch Digital LCD Programmable Timer -Programmable timer for use in AC switching applications. Onboard battery maintains time and settings. DIN rail mountable. - timers-and-controls - 111 1” and “H+” at same time to set the hours.
               (3)press the “111 1 - DIN Rail Time Relay Switch Digital LCD Programmable Timer -Programmable timer for use in AC switching applications. Onboard battery maintains time and settings. DIN rail mountable. - timers-and-controls - 111 1” and “M+” at same time to set the mins.
               (4)press the “MANUAL” will display “AUTO ON” or “AUTO OFF”
               (5)press the “MANUAL” can change the status,”ON” is normally open,”OFF” is normally off.

Additional information

Weight.15 kg
Dimensions10 × 7 × 8 cm

Reviews

There are no reviews yet.

Be the first to review “DIN Rail Time Relay Switch Digital LCD Programmable Timer”