jpg_0070 Voltage Controlled Switch Module

Voltage Controlled Switch Module

$24.99

Battery charge and discharge programmable intelligent controller

 

Specifications:
Output Capacity: Can Control Loads within a range of DC 30V or AC 220V 10A
Power Supply Voltage: DC 12V
Test Voltage Range: DC 0-30V
Static Current: 20mA
Working Current: 50mA
Working Temperature: -40-85°C
PCB Size: 64 * 40 * 18mm / 2.52 * 1.57 * 0.7in (L * W * H)
PCB Weight: 27g / 0.96oz

Compare

Description

Battery Monitor and Voltage Controlled Switch Module

Product Introduction:

Battery charge and discharge module with integrated voltmeter undervoltage and overvoltage protection timing charge and discharge with serial communication function.

Module Features:

  1. Battery charge and discharge intelligent controller

  2. Module maintains programming mode when power is removed.

  3. Programmable charge and discharge times

  4. Serial communication (TTL Level) function with real-time monitoring of the working status of the switch module

  5. Additional signal output (TTL Level) tied to relay actuation that can be used to control other equipment.

  6. Emergency stop function (E-STOP button). Pressing the stop button at any time will immediately disengage the relay.

Variables:

Voltage upper limit: UL1, voltage lower limit nL1, the voltage upper limit is greater than the voltage lower limit (UL1> nL1)

Operating modes:

U-1: Voltage management: When the measured voltage is lower than the lower limit voltage the relay will engage. It will remain engaged until the upper limit voltage is reached. This function is normally used to engage a generator for battery changing applications triggered by low voltage conditions.

U-2: Timed charging: When the measured voltage is lower than the lower limit voltage, the relay will engage and then start a countdown (OP time). At end of the time delay, the relay will disengage or when the measured voltage is higher than the upper limit voltage the relay will disengage. This function is normally used for actuating battery bank switching apperatus.

U-3: High battery charge detection: When the measured voltage is higher than the upper limit voltage, the relay will engage. When the voltage is below the lower limit voltage, the relay will disengag. This is useful for automatically employing a dump load for over-voltage conditions.

U-4: High battery charge detection with time control: set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage below the lower limit voltage , The relay is disconnected;

U-5: In-range voltage detection – : The relay will engage and remain engaged only when the measured voltage is between the upper and lower limits. As soon as the voltage is outside the set points, the relay will diesngage.

U-6: Outside of range voltage detection: The relay will engage and remain engaged only when the measured voltage is outside of the set voltage range. (Above the upper or below the lower set voltages).

Device Specifications:

Power supply voltage: DC6—40V

Voltage detection range: DC 0—60V

Voltage measurement error: ± 0.1V

Charge and discharge time (OP) range: 0 – 999 minutes

How do I set parameters?

1. First, detemine what functions you require based on the above function list.

2. When the module is powered on, it will flash the current mode of operation (default U-1 mode) and then enter the main interface. Press the SET button for 2 seconds and then release to enter setup. Using the UP and DOWN buttons, select the mode to be set (U-1 ~ U-6).

3. After selecting the mode, press the SET button to set the corresponding parameter. The parameter to be set will flash (UL1 voltage upper limit, nL1 voltage lower limit, OP conduction time), press UP, DOWN Key to increase or decrease the value. Press the SET button to set the current mode of the next parameter, using the process above.

4. Set the parameters and then press the SET button for 2 seconds to store. The current setting mode will flash, and then return to the main interface.

5. In the main interface, press the DOWN key to achieve voltage and time switching.

Mode selection interface: Press the SET button for a long time to enter the mode selection interface, set the finished, a long time press the SET button and then release the exit mode selection interface, back to the main interface.

 

Additional features:

1. Data upload: through the serial port to achieve data upload, interval 1s upload a voltage and run time, easy to post-data analysis;

2. Serial port settings parameters: You can set the mode and parameters through the serial port, more convenient;

3. An extra signal output, when the relay to meet the conditions, the output high, the other output low.

Serial port control (TTL level communication)

Communication protocol standard:

The baud rate is 115200 bps

Data bits: 8

Stop bit: 1

Check digit: none

Flow control: none

Serial commands:

“U-1”: Operating mode (range U-1 to U-6)

“000”: 0 – does not enable timing function, non-0 – enable timing function (range 001 to 999)

“Dw02.9”: Set the lower limit voltage

“Up10.1”: set the upper limit voltage (range 00.0V ~ 99.9V)

“Get”: Get the current settings

“On”: Allows the relay to turn on

“Off”: Always turn off the relay

“Start”: start uploading data

“Stop”: stop uploading data

The above command can be any combination of two, need to be separated by commas

Such as: “dw02.9, up10.1” set the lower limit voltage 02.9V upper limit voltage 10.1V

Upload Status: Test Voltage + On Time + Status

“00.0V, 00: 00: 00, OP \ r \ n”

00.0V: Measured voltage

00:00:00: Relay on time

Status: OP relay on, CL relay off

STOP key function expansion:

Relay enable mode:

1. ON: OP conduction time, the relay allows conduction;

2. OFF: The relay is disabled and is always off;

Press the STOP button on the main interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is an emergency stop function, a key to disconnect the relay)

Sleep mode:

1. C-P sleep mode: After five minutes without any key press, the digital display will automatically shut down. The module will continue normal operation.

2. O-d normal mode: digital tube is always open display;

Press and hold the STOP button for 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.

Battery Monitor and Voltage Controlled Switch Module

Product Introduction:

Battery charge and discharge module with integrated voltmeter undervoltage and overvoltage protection timing charge and discharge with serial communication function.

Module Features:

  1. Battery charge and discharge intelligent controller

  2. Module maintains programming mode when power is removed.

  3. Programmable charge and discharge times

  4. Serial communication (TTL Level) function with real-time monitoring of the working status of the switch module

  5. Additional signal output (TTL Level) tied to relay actuation that can be used to control other equipment.

  6. Emergency stop function (E-STOP button). Pressing the stop button at any time will immediately disengage the relay.

Variables:

Voltage upper limit: UL1, voltage lower limit nL1, the voltage upper limit is greater than the voltage lower limit (UL1> nL1)

Operating modes:

U-1: Voltage management: When the measured voltage is lower than the lower limit voltage the relay will engage. It will remain engaged until the upper limit voltage is reached. This function is normally used to engage a generator for battery changing applications triggered by low voltage conditions.

U-2: Timed charging: When the measured voltage is lower than the lower limit voltage, the relay will engage and then start a countdown (OP time). At end of the time delay, the relay will disengage or when the measured voltage is higher than the upper limit voltage the relay will disengage. This function is normally used for actuating battery bank switching apperatus.

U-3: High battery charge detection: When the measured voltage is higher than the upper limit voltage, the relay will engage. When the voltage is below the lower limit voltage, the relay will disengag. This is useful for automatically employing a dump load for over-voltage conditions.

U-4: High battery charge detection with time control: set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage below the lower limit voltage , The relay is disconnected;

U-5: In-range voltage detection – : The relay will engage and remain engaged only when the measured voltage is between the upper and lower limits. As soon as the voltage is outside the set points, the relay will diesngage.

U-6: Outside of range voltage detection: The relay will engage and remain engaged only when the measured voltage is outside of the set voltage range. (Above the upper or below the lower set voltages).

Device Specifications:

Power supply voltage: DC6—40V

Voltage detection range: DC 0—60V

Voltage measurement error: ± 0.1V

Charge and discharge time (OP) range: 0 – 999 minutes

How do I set parameters?

1. First, detemine what functions you require based on the above function list.

2. When the module is powered on, it will flash the current mode of operation (default U-1 mode) and then enter the main interface. Press the SET button for 2 seconds and then release to enter setup. Using the UP and DOWN buttons, select the mode to be set (U-1 ~ U-6).

3. After selecting the mode, press the SET button to set the corresponding parameter. The parameter to be set will flash (UL1 voltage upper limit, nL1 voltage lower limit, OP conduction time), press UP, DOWN Key to increase or decrease the value. Press the SET button to set the current mode of the next parameter, using the process above.

4. Set the parameters and then press the SET button for 2 seconds to store. The current setting mode will flash, and then return to the main interface.

5. In the main interface, press the DOWN key to achieve voltage and time switching.

Mode selection interface: Press the SET button for a long time to enter the mode selection interface, set the finished, a long time press the SET button and then release the exit mode selection interface, back to the main interface.

 

Additional features:

1. Data upload: through the serial port to achieve data upload, interval 1s upload a voltage and run time, easy to post-data analysis;

2. Serial port settings parameters: You can set the mode and parameters through the serial port, more convenient;

3. An extra signal output, when the relay to meet the conditions, the output high, the other output low.

Serial port control (TTL level communication)

Communication protocol standard:

The baud rate is 115200 bps

Data bits: 8

Stop bit: 1

Check digit: none

Flow control: none

Serial commands:

“U-1”: Operating mode (range U-1 to U-6)

“000”: 0 – does not enable timing function, non-0 – enable timing function (range 001 to 999)

“Dw02.9”: Set the lower limit voltage

“Up10.1”: set the upper limit voltage (range 00.0V ~ 99.9V)

“Get”: Get the current settings

“On”: Allows the relay to turn on

“Off”: Always turn off the relay

“Start”: start uploading data

“Stop”: stop uploading data

The above command can be any combination of two, need to be separated by commas

Such as: “dw02.9, up10.1” set the lower limit voltage 02.9V upper limit voltage 10.1V

Upload Status: Test Voltage + On Time + Status

“00.0V, 00: 00: 00, OP \ r \ n”

00.0V: Measured voltage

00:00:00: Relay on time

Status: OP relay on, CL relay off

STOP key function expansion:

Relay enable mode:

1. ON: OP conduction time, the relay allows conduction;

2. OFF: The relay is disabled and is always off;

Press the STOP button on the main interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is an emergency stop function, a key to disconnect the relay)

Sleep mode:

1. C-P sleep mode: After five minutes without any key press, the digital display will automatically shut down. The module will continue normal operation.

2. O-d normal mode: digital tube is always open display;

Press and hold the STOP button for 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.

Additional information